Differential Pressure Transmitter 4-20 MA With Hart Interface - Range 0 To 750 Mmh2o

Differential pressure transmitter 4-20 mA with hart interface - range 0 to 750 mmh2o Differential Pressure Transmitter AT3051 Differential Pressure Transmitter can be used to measure liquid, gas or steam flow as well as liquid level, density and pressure. It outputs a 4~20mA DC signal...

Product Details


Differential pressure transmitter 4-20 mA with hart interface - range 0 to 750 mmh2o

Differential Pressure Transmitter

image

AT3051 Differential Pressure Transmitter can be used to measure liquid, gas or steam flow as well as liquid level, density and pressure. It outputs a 4~20mA DC signal corre-sponding to the measured differential pressure. It also features remote setup and monitoring through communications HART.

Main Features:

1.Capacitive metal sensor

2.Housing can be rotated through 330°C

3.Backlight LCD display for the dark environment

4.Modular design,field key and remote configuration 

 

Certificates:

1.Intrinsic safety certificate 

2.Explosion-proof certificate4.ISO 9001:2000 certificate

 

Application:

Process engineering, chemical industry


SPECIFICATIONS
General Specification
Service
Liquid, gas and vapor applications
Output
4~20mA with Hart
Power Supply
(10.5~45)VDC
Main performance parameters   
Accuracy
±0.1%
Stability
±0.1% of upper range limit (URL) for 10 years. 
Electrical connections
M20*1.5(M),1/2-14NPT,customer
Diaphragm material
SS316L, Hastelloy C
Pressure range
(0.2~6)kPa, (0.4~40)kPa, (2.5~250)kPa, (8~800)kPa, (30~3000)kPa
Environmental protection
IEC IP67
Physical Specifications 
Indicator
An optional 5-digit LCD meter with enginerring unit is also available.
EMC Conformity
EMC(2004/108/EC)
Process connections
1/4-18NPT
Weight
3.1 to 3.6kg without options



blob.png

blob.png


wiring.jpg

AT3051 Order Sheet:

blob.png

blob.png

Installation Site

image


Inquiry