Fully welded pressure transmitter for hygienic applications 3-A sanitary standards, FDA-compliant, EHEDG-certified Resistant to all common CIP cleaning media and SIP-capable (150 °C max, < 30 min) Versions available for high media temperatures (200 °C) Surface roughness connection Ra ≤ 0.8...
Fully welded pressure transmitter for hygienic applications
3-A sanitary standards, FDA-compliant, EHEDG-certified
Resistant to all common CIP cleaning media and SIP-capable (150 °C max, < 30 min)
Versions available for high media temperatures (200 °C)
Surface roughness connection Ra ≤ 0.8 for highest hygienic requirements
Fully welded and compact design for washdowns without residuals
Excellent active temperature compensation for increased process stability
External programming of zero points and span with FlexProgrammer 9701
Absolute pressure, relative pressure, and vacuum measurement
Performance characteristics: -1 … 40 bar
Measuring range:
Min. measuring span of 0.1 bar
Max. measuring the span of 40 bar
Pressure type: Absolute
Relative (gauged)
The standard error of measurement (BFSL)
± 0.04 % FSR
± 0.1 % FSR
Including non-linearity, hysteresis and non-repeatability according BFSL
For turndown, multiply this value by the applied turndown ratio
Max. measuring error
± 0.1 % FSR
± 0.25 % FSR
Including zero-point and span error, nonlinearity (by terminal baseline), hysteresis and non-repeatability (EN 61298-2)
For turndown, multiply this value by the applied turndown ratio
Temperature coefficient
≤ 0.03 % FSR/10 K, measuring the span
≤ 0.03 % FSR/10 K, zero point
Compensated temperature range
-40 … 85 °C
Long term stability
≤ 0.1 % FSR/a , measuring range > 1 bar
≤ 1 mbar , measuring range ≤ 1 bar
Max. turndown ratio
5 : 1
Rise time (10 ... 90 %)
≤ 5 ms
Compliance and approvals
Explosion protection
ATEX II 1/2G Ex ia IIC T4/T6 Ga/Gb
ATEX II 1/2G Ex ia IIC T3/T4/T6 Ga/Gb
ATEX II 1D Ex ia IIIC T107 °C IP6X Da
ATEX II 1G Ex ia IIC T4/T6 Ga
ATEX II 1G Ex ia IIC T3/T4/T6 Ga